SOT-23-5
TPS2061DBVR
The TPS206x power-distribution switches are intended for applications where heavy capacitive loads and short-circuits are likely to be encountered. This device incorporates 70-m; N-channel MOSFET power switches for power-distribution systems that require multiple power switches in a single package. Each switch is controlled by a logic enable input. Gate drive is provided by an internal charge pump designed to control the power-switch rise times and fall times to minimize current surges during switching. The charge pump requires no external components and allows operation from supplies as low as 2.7 V. When the output load exceeds the current-limit threshold or a short is present, the device limits the output current to a safe level by switching into a constant-current mode, pulling the overcurrent logic output low. When continuous heavy overloads and short-circuits increase the power dissipation in the switch, causing the junction temperature to rise, a thermal protection circuit shuts off the switch to prevent damage. Recovery from a thermal shutdown is automatic once the device has cooled sufficiently. Internal circuitry ensures that the switch remains off until valid input voltage is present. This power-distribution switch is designed to set current limit at 1.5 A typically.
Brand
TI
Package
SOT-23-5
Stock
958
Lead Time
In stock
TPS2061DBVR Parameters
| Package | SOT-23-5 |
|---|---|
| Brand | TI |
| Date Code | Within 2 years |
| 类型 | 高侧开关 |
| 工作电压 | 2.7V~5.5V |
| 导通电阻 | 70mΩ |
| Operating Temperature | -40℃~+125℃ |
| Category | Power ElectronicSwitches |
|---|---|
| Stock | 958 |
| MOQ / SPQ | 1 / 1 |
| 输入控制逻辑 | 低电平有效 |
| 最大连续电流 | 1A |
| 功能特性 | 短路保护; 过流保护; 集成电荷泵; 软启动; 过温保护; 欠压锁定 |
TPS2061DBVR Overview
The TPS206x power-distribution switches are intended for applications where heavy capacitive loads and short-circuits are likely to be encountered. This device incorporates 70-m; N-channel MOSFET power switches for power-distribution systems that require multiple power switches in a single package. Each switch is controlled by a logic enable input. Gate drive is provided by an internal charge pump designed to control the power-switch rise times and fall times to minimize current surges during switching. The charge pump requires no external components and allows operation from supplies as low as 2.7 V. When the output load exceeds the current-limit threshold or a short is present, the device limits the output current to a safe level by switching into a constant-current mode, pulling the overcurrent logic output low. When continuous heavy overloads and short-circuits increase the power dissipation in the switch, causing the junction temperature to rise, a thermal protection circuit shuts off the switch to prevent damage. Recovery from a thermal shutdown is automatic once the device has cooled sufficiently. Internal circuitry ensures that the switch remains off until valid input voltage is present. This power-distribution switch is designed to set current limit at 1.5 A typically.
TPS2061DBVR Features
No features are available.
TPS2061DBVR Applications
No applications are available.