TC54VN4202ECB713 is a 4.2V-threshold voltage detector with open-drain output. It senses voltage; it is neither a 4.2V regulator nor a complete battery charger or protection solution. Define the monitored rail, switching window and receiving logic before buying.

1. Decode the complete ordering code

Microchip identifies N as N-channel open drain, 42 as 4.2V, 0 as fixed feature code, 2 as 2% tolerance, E as -40 to +85°C, CB as 3-lead SOT-23A and 713 as standard taping. Do not exchange VN for the VC push-pull variant by name similarity.

The TC54 has hysteresis: the output is pulled low below detection voltage and releases after recovery through the hysteresis interval. Falling detection and rising release are not one identical threshold.

2. Understand the ±2% window

Applying ±2% to nominal 4.2V gives approximately 4.116–4.284V. This illustrates tolerance, not every temperature or dynamic condition; review the applicable datasheet for test conditions, hysteresis and behavior. Do not expect each device to switch at exactly 4.200V.

If a system needs a very narrow switching window, compare tolerance, supply ripple and timing together. A newer manufacturing lot will not repair a specification that cannot meet the required window.

3. Specify the open-drain pull-up

A released open-drain output needs a suitable pull-up path to form a high logic level. Check the pull-up voltage against both output limits and receiving logic. A high monitored rail does not make every connected logic input tolerant of that voltage.

For current illustration only, a 3.3V pull-up through 10kΩ draws about 330µA when low, neglecting output drop; 100kΩ draws about 33µA. Higher resistance lowers low-state current but also interacts with leakage, capacitance, noise and rise time. Do not choose it using power alone.

4. Can it replace a reset IC with delay?

Not on threshold alone. TC54 has no dedicated reset-delay function. Propagation delay is not a programmable post-startup hold interval. If the controller needs reset held after the rail settles, engineering must provide the timing or choose an appropriate device.

Voltage detection does not automatically provide charge control, power switching or complete overcharge/overdischarge protection. Define the detector’s role within the entire battery system.

5. Sample and RFQ checks

Test slow falling input, recovery, disturbances near threshold and power-up. Record detection, release and real output levels. Verify the precise SOT-23A-3 pin map even though the package is small and familiar.

RFQ: TC54VN4202ECB713; quantity ___; monitored rail ___; required switching window ___; pull-up voltage/resistance ___; receiver logic ___; reset hold requirement ___; temperature ___; packing/dates/lots ___; destination and arrival ___.

Frequently asked questions

Can the high output power a load? It is a status output; use it within the specified output conditions.

Does 4.2V establish full lithium-battery protection? No; the complete battery circuit needs its own design and validation.

Product lookup and enquiry

An exact product-detail page on this site was not verified for this code. Submit the complete code through the WOMAIELEC enquiry page. Include quantity, application and the operating conditions above. Price, stock, delivery, lot and document availability require confirmation per order.

Manufacturer references

Manufacturer product reference 1. Reviewed November 17, 2026. This guide does not replace design qualification or guarantee inventory or authenticity.